| Ricardo Series of Standby Generators Specifications |
| Engine Cylinders |
4 |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
6 |
6 |
6 |
| GENSET Model |
15GF(LDE) |
20GF(LDE) |
24GF(LDE) |
30GF(LDE) |
40GF(LDE) |
50GF(LDE) |
64GF(LDE) |
80GF(LDE) |
100GF(LDE) |
120GF(LDE) |
150GF(LDE) |
| Continuous Output |
15KW |
20KW |
24KW |
30KW |
40KW |
50KW |
64KW |
80KW |
100KW |
120KW |
150KW |
| Engine Model |
R495D |
R4100D |
R4100D |
R4105D |
R4105ZD |
R4105ZD |
R6105ZD |
R6105ZD |
R6105AZLD |
R6105IZLD |
R6113ZLD |
| Bore X Stroke (mm) |
95x115 |
100x115 |
100x115 |
105x110 |
105x125 |
105x125 |
105x125 |
105x125 |
105x125 |
105x125 |
113X125 |
| Tot Displacement (Litres) |
3.26 |
3.61 |
3.61 |
3.81 |
4.33 |
4.33 |
6.49 |
6.49 |
6.96 |
6.96 |
7.52 |
| Compression Ratio |
16.5:1 |
17.5:1 |
17.5:1 |
19.5:1 |
16:1 |
16:1 |
16:1 |
16:1 |
16:1 |
16:1 |
16:1 |
| Induction System |
natural |
natural |
natural |
natural |
natural |
natural |
natural |
turbo |
turbo |
turbo |
turbo |
| Rated output (KW) |
26KW |
30.1KW |
30.1KW |
36.4KW |
56KW |
56KW |
90KW |
90KW |
110KW |
134KW |
175KW |
| Fuel consumption (grams/KWh) |
max 251.6 |
max 251.6 |
max 251.6 |
max 251.6 |
max 232 |
max 232 |
max 224 |
max 224 |
max 218 |
max 215 |
max 225 |
| Oil consumption (grams/KWh) |
1.38 |
1.4 |
1.4 |
1.4 |
1.63 |
1.63 |
max 1.63 |
max 1.63 |
max 1.63 |
max 1.63 |
max 1.54 |
| Engine Type |
Water-cooled, Four-stroke, in-line, direct injection, diesel |
| Engine Rated speed (rpm) |
ENGINES Fitted with electronic Governors 1500Rpm |
| Engine Cooling Method |
Water-cooled with radiator |
| Engine Starting Method |
D.C. 12v or 24v electric starting |
| Alternator Model STAMFORD |
|
BCI184F |
BCI184F |
BCI184F |
UCI224D |
UCI224F |
UCI224G |
UCI274G |
UCI274E |
UCI274F |
UCI 274H |
| Alternator Rated power |
15KW |
20KW |
25KW |
30KW |
40KW |
50KW |
64KW |
80KW |
100KW |
120KW |
150KW |
| Alternator Rated voltage |
380/220, 400/230, 220v, 230v etc. |
| Alternator Rated current |
According to selected voltage and phase |
| Alternator Rated frequency |
50HZ |
| Alternator Rated speed (rpm) |
1500 |
| Alternator Power factor |
1 for single phase, 0.8 lagging for 3-phase |
| Alternator Phase connection |
1-phase or 3-phase |
| Alternator Winding connection |
3 or 4 wire connected (12 wire for 3-phase) |
| Alternator Excitation Method |
Brushless |
| Control Panel |
V-meter, A-meter, Frequency meter, circuit breaker, transfer switch, AVR, temp. and pressure gauges, indicating lamp, hour meter, key starter etc. |
| GENSET Gross / Net Wt (kg) |
960/900 |
980/920 |
1000/940 |
1100/1000 |
1100/1000 |
1180/1080 |
2100/2000 |
2150/2050 |
2550/2450 |
2600/2500 |
2800/2650 |
| GENSET Packing Size (metres) |
2.0x0.96x1.1 |
2.0x0.96x1.1 |
2.0x0.96x1.1 |
2.3x1.1x1.3 |
2.3x1.1x1.3 |
2.3x1.1x1.3 |
2.8x1.3x1.65 |
2.8x1.3x1.65 |
2.85x1.3x1.65 |
2.85x1.3x1.65 |
3.2x1.45x1.73 |
| Please Note: |
Prices exclude GST; All prices and technical data subject to change without notice. |
| OpenSet Price NZ$ |
|
|
|
|
|
|
|
|
|
|
|
| LowNoise Price NZ$ |
|
|
|
|
|
|
|
|
|
|
|
| AMF/Heat add NZ$ |
1,200 |
1,300 |
1,300 |
1,300 |
1,400 |
1,500 |
1,600 |
1,600 |
1,900 |
2,100 |
2,500 |
| OpenSet Price AU$ |
|
|
|
|
|
|
|
|
|
|
|
| LowNoise Price AU$ |
|
|
|
|
|
|
|
|
|
|
|
| AMF/Heat add AU$ |
|
|
|
|
|
|
|
|
|
|
|